finish /clear,start /Title,Einzelentladungskrater bei der Mikrofunkenerosion /prep7 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Parameter we=60e-6 ![J] d=20e-6 ![m] te=1 te1=0.4e-6 ![s] te2=10 Qq=0.12*we/(3.1416*(d/2)*(d/2)*te1) !Wärmestromdichte [W/m²] Tu=20 !Umgebungstemperatur n=50 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Definition des Elemtetyps ET,1,PLANE77 !55 !!!!!!!!!!!!!!!!! MPTEMP,1,20,90,200,315,425,500 mpdata,kxx,1,1,7.2,7.5,8.5,9.8,11.0,12.1 !Thermische Leitfähigkeit [W/(m²K)] mpdata,c,1,1,560,570,600,650,700,740 !Thermische Kapazität [J/(kg K)] mp,dens,1,4450 !Dichte [kg/m³] !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Geometrie rectng,-2*d,6*d,0,3*d rectng,,4*d,0,d AOVLAP,1,2 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Meshing Parameter LESIZE,5,,,4*n LESIZE,8,,,n !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Meshing MSHAPE,0,2D MSHKEY,1 AMESH,2 MSHAPE,1,2D MSHKEY,0 AMESH,3 finish !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Lastschritte... /SOLU ANTYPE,TRANS,NEW !Berechnung wird transient durchgeführt TINTP,,,,1 !Zeit-Integrationsparameter (Methode nach Euler Rückwärtseinsetzen) OUTRES,all,all autots,on lsel,s,,,9 lsel,a,,,4 lsel,a,,,3 lsel,a,,,2 lsel,a,,,10 nsll,s,1 d,all,temp,TU alls !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Lastschritt 1 (Zimmertemp) TIMINT,OFF !Ausstellen der transienten Efffekte time,te NSUB,5 !Zeit am Ende dieses Lastfalls D,ALL,TEMP,TU !Zimmertemp alls solve !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!2.Lastschritt-Aufwärmen TIMINT,on TIME,te+te1 ddel,all,temp NSEL,S,LOC,Y,0 NSEL,r,LOC,X,d+d/2,2*d+d/2 SF,all,hflux,Qq neqit,200 deltim,te1/10,te1/20,te1/5 kbc,1 alls Solve !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !3.Lastschritt-Abkühlen /solu time,te+te1+te2 NSEL,S,LOC,Y,0 NSEL,r,LOC,X,d+d/2,2*d+d/2 SFDEL,all,HFLUX alls NSEL,S,LOC,Y,0 NSEL,r,LOC,X,d+d/2,2*d+d/2 SF,all,conv,1500,20 alls neqit,200 deltime,te2/10,/te2/20,te2/5 kbc,1 alls solve finish !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !Strukturanalyse /prep7 ET,2,PLANE82 !42 etchg,tts !Elementtyp von tehrm. auf Strukturanalyse umschaltenplane55 etlist !!!!!!!!!!!!!Materialdaten für Strukturanalyse MPTEMP,1,20,90,200,315,425,500 mpdata,alpx,1,1,8.8e-6,9.0e-6,9.3e-6,9.6e-6,9.8e-6,10e-6 mpdata,ex,1,1,113e+9,107.35e+9,101.7e+9,92.66e+9,84.75e+9,70.06e+9 mp,prxy,1,0.361 !!!!!plastische Verformungsoption!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! tb,BKIN,1,6,,1 ! Bilinear Kinematic Hardening für 6 Temp. TBTEMP,20 TBDATA,1,900e+6,11.0e+9 !0.2 Streckgrenze und Tangentenmodul 1/10 TBTEMP,90 TBDATA,1,810e+6,10.2e+9 TBTEMP,200 TBDATA,1,630e+6,9.4e+9 TBTEMP,315 TBDATA,1,580e+6,9.0e+9 TBTEMP,425 TBDATA,1,540e+6,8.3e+9 TBTEMP,500 TBDATA,1,500e+6,7.8e+9 TBLIST,BKIN,1 /XRANGE,0,0.02 TBPLOT,BKIN,1 finish !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! /solu antype,trans !static outpr,all,all nlgeom,on autots,on !!Einspannung lsel,s,,,3 nsll,s,1 d,all,uy d,all,ux alls eplot !!!Daten der thermischen Berechnung auf das Modell transferieren! !!!für jeden einzelnen SubStep der th.Sim. eine Strukturlösung berechnen! !!!!!1.Lastschritt TU=20°C S=0 *Do,p,1,1 *Do,q,1,3 ldread,temp,1,1,,,,rth S=S+1 TIME,(te*S)/3 kbc,0 NSUB,5 neqit,200 solve *EndDo *EndDo !!!!!!!!!!!für Aufwärmvorgang k=0 *Do,i,2,2 *Do,j,1,9 ldread,temp,i,j,,,,rth !NSEL,S,LOC,Y,0 !NSEL,r,LOC,X,d+d/2,2*d+d/2 !SF,all,pres,1000 k=k+1 TIME,te+(te1*k)/9 neqit,200 kbc,0 NSUB,5 solve *EndDo *EndDo !!!!!!!!!!!für Abkühlvorgang R=0 *Do,l,3,3 *Do,m,1,6 ldread,temp,l,m,,,,rth R=R+1 TIME,te+te1+(te2*R)/6 neqit,200 kbc,0 NSUB,5 solve *EndDo *EndDo !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! finish !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! /post26 !nsol,2,200,u,y ! Verschiebung in Y-Richtung nsol,2,200,temp lines,1000 ! Anzahl der max.Zeilen prvar,2 ! Auflisten der Werte