/NOPR ! Suppress printing of UNDO process /PMACRO ! Echo following commands to log FINISH ! Make sure we are at BEGIN level /CLEAR,NOSTART ! Clear model since no SAVE found /PREP7 smrt,off /NOPR ANTYPE,STATIC ! STATIC ANALYSIS NLGEOM,ON ! LARGE DEFLECTION OPTION LUMPM,ON ! ET,1,BEAM188 ET,2,MPC184,6 ET,3,MPC184,1 MP,EX,1,30E5 MP,PRXY,1,0.33 MP,DENS,1,10.0 SECTYPE, 1, BEAM, RECT SECDATA, .1, .1 ! LOCAL,11,0, 0,0,0,0,0,-90 LOCAL,12,0, 0,0,0,0,0,-90 CSYS,0 ! TB,JOIN,10,1,5,JNS4 !Change table data TBPT,,0.0,0 TBPT,,0.2,2 TBPT,,0.4,2.1 TBPT,,0.6,5 TBPT,,0.8,5.1 ! n,1,0,0,0 n,2,0,1,0 n,3,0,1,0 n,4,1,1,0 ! TYPE,1 MAT, 1 SECNUM,1 e,1,2 e,3,4 TYPE,3 e,1,2 e,3,4 ! SECTYPE,2,JOIN,REVO,TESTING04 ! DEFINING REVOLUTE JOINT SECJ,,11,12 ! TYPE,2 SECNUM,2 MAT,10 e,2,3 ! ! d,1,all f,4,mz,5.1 !* FINISH /SOL solcontrol,on outpr,all OUTRES,all,all DELTIM,0.01, 0.002, 0.1 NEQIT,150 SOLVE ! SOLVE FIRST LOAD STEP FINISH ! /POST26 NUMVAR,200 SOLU,191,NCMIT STORE,MERGE FILLDATA,191,,,,1,1 REALVAR,191,191 !* NSOL,2,4,ROT,Z, ROTZ_2 RFORCE,3,1,M,Z, MZ_3 STORE,MERGE XVAR,1 !* PLVAR,2, )/GOP ! Resume printing after UNDO process )! We suggest a save at this point