INIT MASTER(S) ID D:\xxxx.,MSC.v SOL SESTATICS TIME 10000 CEND ECHO = NONE DISPLACEMENT = ALL SPCFORCE = ALL FORCE = ALL STRESS = ALL LOAD = 3 BEGIN BULK $ PARAM,AUTOSPC,NO PARAM,K6ROT,100. PARAM,MAXRATIO,1.E+8 PARAM,WTMASS,.00259 PARAM,GRDPNT,1 PARAM,INREL,-1 CORD2C 1 0 0. 0. 0. 0. 0. 1.+MSC.VC1 +MSC.VC1 1. 0. 1. CORD2S 2 0 0. 0. 0. 0. 0. 1.+MSC.VC2 +MSC.VC2 1. 0. 1. $ MSC.visualNastran for Windows Load Set 1 : xxx TEMPD 1 0. TEMP 1 1 100. TEMP 1 4 100. $ MSC.visualNastran for Windows Load Set 2 : xxx FORCE 2 4 0 1. 1000. 0. 0. $ MSC.visualNastran for Windows Load Set 3 : xxx FORCE 3 1 0 1. 1000. 0. 0. $ MSC.visualNastran for Windows Constraint Set 1 : xxx SUPORT 1 123456 $ MSC.visualNastran for Windows Property 1 : Untitled PBAR 1 1 78.5067 490.874 490.874 980.921 0. +PR 1 +PR 1 0. -5. 5. 0. 0. 5. -5. 0.+PA 1 +PA 1 0.88653 0.88652 0. $ MSC.visualNastran for Windows Material 1 : St MAT1 1 210000. 0.3 7.85E-9 1.2E-5 0. GRID 1 0 0. 0. 0. 0 GRID 4 0 5. 0. 0. 0 GRID 5 0 20. 0. 0. 0 GRID 6 0 35. 0. 0. 0 GRID 7 0 50. 0. 0. 0 CBAR 1 1 1 4 0.26726 0.53452 0.80178 CBAR 2 1 4 5 0.26726 0.53452 0.80178 CBAR 3 1 5 6 0.26726 0.53452 0.80178 CBAR 4 1 6 7 0.26726 0.53452 0.80178 ENDDATA