/COM,ANSYS RELEASE 14.5 UP20120918 12:58:29 03/03/2014 *** WARNING *** CP = 2.371 TIME= 12:58:32 Element shape checking is currently inactive. Issue SHPP,ON or SHPP,WARN to reactivate, if desired. *** WARNING *** CP = 5.164 TIME= 12:58:35 Material number 8 (used by element 15980 ) should normally have at least one MP or one TB type command associated with it. Output of energy by material may not be available. *** WARNING *** CP = 9.937 TIME= 12:58:38 Coefficient ratio exceeds 1.0e8 - Check results. *** WARNING *** CP = 23.119 TIME= 12:58:53 A reference force value times the tolerance is used by the Newton-Raphson method for checking convergence. The calculated reference FORCE CONVERGENCE VALUE = 2.619569762E-18 is less than a threshold. This threshold defaults to 1.0-2 or is specified as MINREF on the CNVTOL command. Check results carefully. *** WARNING *** CP = 45.661 TIME= 12:59:14 A reference force value times the tolerance is used by the Newton-Raphson method for checking convergence. The calculated reference FORCE CONVERGENCE VALUE = 6.371428851E-19 is less than a threshold. This threshold defaults to 1.0-2 or is specified as MINREF on the CNVTOL command. Check results carefully. *** WARNING *** CP = 67.907 TIME= 12:59:37 A reference force value times the tolerance is used by the Newton-Raphson method for checking convergence. The calculated reference FORCE CONVERGENCE VALUE = 2.630174425E-19 is less than a threshold. This threshold defaults to 1.0-2 or is specified as MINREF on the CNVTOL command. Check results carefully. *** WARNING *** CP = 90.746 TIME= 12:59:59 A reference force value times the tolerance is used by the Newton-Raphson method for checking convergence. The calculated reference FORCE CONVERGENCE VALUE = 4.258429594E-16 is less than a threshold. This threshold defaults to 1.0-2 or is specified as MINREF on the CNVTOL command. Check results carefully. *** WARNING *** CP = 95.831 TIME= 13:00:03 Material number 8 (used by element 15980 ) should normally have at least one MP or one TB type command associated with it. Output of energy by material may not be available. *** WARNING *** CP = 244.282 TIME= 13:02:29 Material number 8 (used by element 15980 ) should normally have at least one MP or one TB type command associated with it. Output of energy by material may not be available. *** WARNING *** CP = 429.845 TIME= 13:05:55 During this session the elapsed time exceeds the CPU time by 58%. Often this indicates either a lack of physical memory (RAM) required to efficiently handle this simulation or it indicates a particularly slow hard drive configuration. This simulation can be expected to run faster on identical hardware if additional RAM or a faster hard drive configuration is made available. For more details, please see the ANSYS Performance Guide which is part of the ANSYS Help system.