/COM, /COM,Preferences for GUI filtering have been set to display: /COM, Structural /COM, Thermal /COM, ANSYS Fluid /COM, FLOTRAN CFD /COM, Magnetic-Nodal /COM, Magnetic-Edge /COM, High Frequency /COM, Electric !* /PREP7 !* ET,1,SOLID5 !* KEYOPT,1,1,3 KEYOPT,1,3,0 KEYOPT,1,5,0 !* !* MPTEMP,,,,,,,, MPTEMP,1,0 MPDATA,EX,1,,210000 MPDATA,PRXY,1,,0.33 MPTEMP,,,,,,,, MPTEMP,1,0 MPDATA,RSVX,1,,10e-9 BLOCK,0,0.1,0,0.02,0,0.02, BLOCK,0,0.1,0.021,0.041,0,0.02, /USER, 1 /VIEW, 1, -0.418384899544E-01, -0.575557044287E-01, 0.997465228289 /ANG, 1, 0.471872190196E-01 /REPLO TYPE, 1 MAT, 1 REAL, ESYS, 0 SECNUM, !* ESIZE,0.003,0, MSHAPE,0,3D MSHKEY,1 !* CM,_Y,VOLU VSEL, , , , 1 CM,_Y1,VOLU CHKMSH,'VOLU' CMSEL,S,_Y !* VMESH,_Y1 !* CMDELE,_Y CMDELE,_Y1 CMDELE,_Y2 !* VPLOT ESIZE,0.005,0, CM,_Y,VOLU VSEL, , , , 2 CM,_Y1,VOLU CHKMSH,'VOLU' CMSEL,S,_Y !* VMESH,_Y1 !* CMDELE,_Y CMDELE,_Y1 CMDELE,_Y2 !* /UI,MESH,OFF /REPLOT !* !* /COM, CONTACT PAIR CREATION - START CM,_NODECM,NODE CM,_ELEMCM,ELEM CM,_KPCM,KP CM,_LINECM,LINE CM,_AREACM,AREA CM,_VOLUCM,VOLU /GSAV,cwz,gsav,,temp MP,MU,1, MAT,1 R,3 REAL,3 ET,2,170 ET,3,174 KEYOPT,3,9,0 KEYOPT,3,10,2 R,3, RMORE, RMORE,,0 RMORE,18e-9 KEYOPT,3,1,5 ! Generate the target surface ASEL,S,,,4 CM,_TARGET,AREA TYPE,2 NSLA,S,1 ESLN,S,0 ESLL,U ESEL,U,ENAME,,188,189 ESURF CMSEL,S,_ELEMCM ! Generate the contact surface ASEL,S,,,9 CM,_CONTACT,AREA TYPE,3 NSLA,S,1 ESLN,S,0 ESURF !* Create Companion Pair - Start R,4 REAL,4 ET,4,170 ET,5,174 KEYOPT,5,9,0 KEYOPT,5,10,2 R,4, RMORE, RMORE,,0 RMORE,18e-9 KEYOPT,5,1,5 TYPE,4 ESEL,S,TYPE,,3 NSLE,S ESLN,S,0 ESURF TYPE,5 ESEL,S,TYPE,,2 NSLE,S ESLN,S,0 ESURF !* Create Companion Pair - End ALLSEL ESEL,ALL ESEL,S,TYPE,,2 ESEL,A,TYPE,,3 ESEL,R,REAL,,3 /PSYMB,ESYS,1 /PNUM,TYPE,1 /NUM,1 EPLOT ESEL,ALL ESEL,S,TYPE,,2 ESEL,A,TYPE,,3 ESEL,R,REAL,,3 ESEL,A,TYPE,,4 ESEL,A,TYPE,,5 CMSEL,A,_NODECM CMDEL,_NODECM CMSEL,A,_ELEMCM CMDEL,_ELEMCM CMSEL,S,_KPCM CMDEL,_KPCM CMSEL,S,_LINECM CMDEL,_LINECM CMSEL,S,_AREACM CMDEL,_AREACM CMSEL,S,_VOLUCM CMDEL,_VOLUCM /GRES,cwz,gsav CMDEL,_TARGET CMDEL,_CONTACT /COM, CONTACT PAIR CREATION - END /MREP,EPLOT VPLOT /REPLOT !---------------- alls nsel,s,loc,x,50/1000,60/1000 nsel,r,loc,y cm,volt_unten,node alls nsel,s,loc,x,50/1000,60/1000 nsel,r,loc,y,41/1000 cm,volt_oben,node alls nsel,s,loc,x nsel,r,loc,y,0,20/1000 cm,unten,node alls nsel,s,loc,x nsel,r,loc,y,20.5/1000,42/1000 cm,oben,node alls cmsel,s,unten,node d,all,ux,0 d,all,uy,0 d,all,uz,0 alls cmsel,s,oben,node d,all,ux,0 d,all,uy,0 d,all,uz,0 alls nsel,s,loc,x,100/1000 nsel,r,loc,y,0,20.5/1000 cm,konvektion,node alls nsel,s,loc,x,100/1000 nsel,r,loc,y,41/1000 cm,hub,node alls !nsel,s,node,,all !d,node,temp,1 !d,node,volt,1 !d,node,mag,1 alls /SOL anty,trans NLGEOM,1 cmsel,s,hub,node d,hub,uy,-2/1000 !time,1e-7 nsubst,5,5 time,1 kbc,0 alls solve alls d,all,volt,0 !d,all,temp,0 d,all,mag !cmsel,s,konvektion,node !sf,all,conv,2,20 alls time,1.00000001 nsubst,1 save alls solve !ddel,all,temp ddel,all,volt alls cmsel,s,volt_unten,node d,all,volt,0 alls cmsel,s,volt_oben,node d,all,volt,1000 alls timint,on,elect autots,on time,2 nsubst,10,10,1 kbc,1 outres,all,1 save alls solve !Lastfall 2 Einprägen der Spannungen finish