*Heading ** Job name: Job-explizit Model name: Model-explizit *Preprint, echo=NO, model=NO, history=NO, contact=NO ** ** PARTS ** *Part, name=Part-1 *Node 1, 0., 0. 2, 0., 5. 3, 0., 10. 4, 0., 15. 5, 0., 20. 6, 0., 25. 7, 0., 30. 8, 0., 35. 9, 0., 40. 10, 0., 45. 11, 0., 50. 12, 0., 55. 13, 0., 60. 14, 0., 65. 15, 0., 70. 16, 0., 75. 17, 0., 80. 18, 0., 85. 19, 0., 90. 20, 0., 95. 21, 0., 100. *Element, type=B21 1, 1, 2 2, 2, 3 3, 3, 4 4, 4, 5 5, 5, 6 6, 6, 7 7, 7, 8 8, 8, 9 9, 9, 10 10, 10, 11 11, 11, 12 12, 12, 13 13, 13, 14 14, 14, 15 15, 15, 16 16, 16, 17 17, 17, 18 18, 18, 19 19, 19, 20 20, 20, 21 *Nset, nset=_PickedSet2, internal, generate 1, 21, 1 *Elset, elset=_PickedSet2, internal, generate 1, 20, 1 *Nset, nset=_PickedSet3, internal, generate 1, 21, 1 *Elset, elset=_PickedSet3, internal, generate 1, 20, 1 ** Section: Section-Balken Profile: Profile-1 *Beam Section, elset=_PickedSet2, material=Stahl, poisson = 0.3, temperature=GRADIENTS, section=RECT 10., 10. 0.,0.,-1. *End Part ** ** ** ASSEMBLY ** *Assembly, name=Assembly ** *Instance, name=Part-1-1, Library=Job-statisch *Import, Step=Step-statisch, Increment=AUTOMATIC_GLOBAL, State=yes, Update=no *End Instance ** *Nset, nset=_PickedSet6, internal, instance=Part-1-1 1, *Nset, nset=_PickedSet7, internal, instance=Part-1-1 21, *End Assembly *Amplitude, name=Amp-1 0., 0., 1., 1. *Amplitude, name=Amp-2 0., 1., 1., 0. ** ** MATERIALS ** *Material, name=Stahl *Density 7.85e-09, *Elastic 210000., 0.3 ** ** BOUNDARY CONDITIONS ** ** Name: BC-Balken Type: Displacement/Rotation *Boundary _PickedSet6, 1, 1 _PickedSet6, 2, 2 _PickedSet6, 6, 6 ** ---------------------------------------------------------------- ** ** STEP: Step-explizit ** *Step, name=Step-explizit *Dynamic, Explicit , 1. *Bulk Viscosity 0.06, 1.2 ** ** LOADS ** ** Name: Load-1 Type: Concentrated force *Cload, amplitude=Amp-2 _PickedSet7, 1, -10000. ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT *End Step