FINISH ! closes procedures /CLEAR,Start ! clear database !---local parameters--------------------------------------------------------- *SET,Pi,4*ATAN(1) ! Pi *SET,g,9806.6 ! g in [mm*s^-2] *SET,a_jib,0 ! Jib angle in [deg] *SET,SWL,1 ! Unit load *SET,JIBLEN,10000 ! beam length [mm] *SET,CYLLEN,2000 ! distance from fixed point to floating bearing *SET,HPIVOT,1500 ! section height 1 *SET,WPIVOT,500 ! section width 1 *SET,HCYL,1500 ! section height 2 *SET,WCYL,500 ! section width 2 *SET,HHEAD,1500 ! section height 3 *SET,WHEAD,500 ! section width 3 *SET,TWEB,15 ! thickness, web plates [mm] *SET,TTOP,15 ! thickness, top flange [mm] *SET,TBTM,15 ! thickness, bottom flange [mm] !---Preprocessing--------------------------------------------------------- /PREP7 ET,1,BEAM189 MPTEMP,,,,,,,, MPTEMP,1,0 MPDATA,EX,1,,210000 MPDATA,PRXY,1,,0.3 ! section 1 SECTYPE,1,BEAM,HREC,,0 SECOFFSET,CENT SECDATA,WCYL,HCYL,TWEB,TWEB,TTOP,TBTM,0,0,0,0 ! section 2 SECTYPE,2,BEAM,HREC,,0 SECOFFSET,USER,WHEAD/2,HCYL/2 SECDATA,WHEAD,HHEAD,TWEB,TWEB,TTOP,TBTM,0,0,0,0 ! section 3 SECTYPE,3,BEAM,HREC,,0 SECOFFSET,USER,WPIVOT/2,-((HCYL/2)-HPIVOT) SECDATA,WPIVOT,HPIVOT,TWEB,TWEB,TTOP,TBTM,0,0,0,0 SECTYPE,4,TAPER, , SECDATA,1,0,0,0, SECDATA,2,JIBLEN-CYLLEN,0,0, SECTYPE,5,TAPER, , SECDATA,1,0,0,0, SECDATA,3,-CYLLEN,0,0, K,1,0,0,0, K,2,JIBLEN-CYLLEN,0,0, K,3,-CYLLEN,0,0 !---Meshing LSTR,1,2 LSTR,1,3 TYPE,1 MAT,1 REAL, ESYS,0 SECNUM,4 !LESIZE,1,,,5 LESIZE,1,1000 LMESH,1 TYPE,1 MAT,1 REAL, ESYS,0 SECNUM,5 !LESIZE,2,,,3 LESIZE,2,1000 LMESH,2 /ESHAPE,1.0 /EFACET,1 /VIEW,1,,1 /REPLOT !---Loads and Constraints DK,1,UY,,,0,UZ,ROTX,ROTZ ! Constraint on Keypoint 1, DK,3,UX,,,0,UY,UZ,ROTX,ROTZ ! Constraint on Keypoint 3, FK,2,FZ,SWL*g*cos(a_jib*pi/180) ! Force on Keypoint 2 [N], bending FK,2,FX,-SWL*g*sin(a_jib*pi/180) ! Force on Keypoint 2 [N], compression FINISH ! leave pre-processor !---start analysis /SOLU ! Solution-Processor ANTYPE,static ! set analysis type SOLVE ! solve FINISH ! leave solution processor !---General Postproc /POST1 /WIND,ALL,OFF /WIND,1,TOP /WIND,2,BOT /GCMD,1,PLNSOL,UZ /GCMD,2,PLNSOL,UX GPLOT