Subject: [PR-05852583] extra parts added to parts list and PSE out of sync Description of Problem: Priority: 1 OF FastTrack: . OF Confirmation: PR Matrix: 6a,b,c ============================ Problem Description: Parts list is created with extra (non-existant) components. NO SYSLOG ERRORS. Conferred with TCE support Reference the following PR's: PR 1604703 reports a similar issue - this case involved components deleted from an assembly - corrupted part. PR 1603437 reports an issue in which the NX to PSE sync is not working as expected. PR 1592542 reports an issue in which the attribute "$~C" is used, the parts list does not display correct members, and the PSE contains entries which are incorrect. Apparently the Parts list and the PSE are unable to synchronize. Previous similar PR's indicate this is due to a part corruption. Customer requests the file(s) be repaired. ============================================================================= Unigraphics Version(s): NX4.0.4.2 See Coordinator Notepad for file location Part: 00000251-501_D (drawing) and 00000251-501_02 (model) Macro: n/a Syslog: n/a Other Files: n/a Work Around: n/a Walk Thru: Customer opens _D file. Creating a parts list causes parts list to contain extra components that are not members of the assembly. Problem is part specific: Yes Problem is OS specific: No Platform Information- Problem is platform specific: No Problem verified on the following platforms and OS versions: Windows XP SP2 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ For further information, please contact Ron Young at (800)955-0000, opt 3, PR# ***** <<<<< This PR has been closed. The resolution was: >>>>> ***** You reported an issue in which extra parts were added to a parts list when opening a drawing from Teamcenter. We provided a new environment varaible,UGII_UGMGR_CLEAN_INTERNAL_PLIST, that users can set to invoke a clean up function to remove the corrupted internal layer zero parts list during open model from Teamcenter. The 00000251-501_D was used to verify the result. A MP request for NX4.0.4 has been submitted. PR Number : 5852583 Date Opened: 13-nov-2007 Status : QN Priority : 1 Family : NX Application: UGMANAGER Category : UNDETERMINED Release : V4.0.4 Platform : INTL64 OS : WINDOW OS Version : XP32_SP2 Terminal : OTHER Platform specific: Undetermined -- End of document --