*Heading ** Job name: 5mu_zykl Model name: Model-1 ** Generated by: Abaqus/CAE 6.14-1 *Preprint, echo=NO, model=NO, history=NO, contact=NO ** ** PARTS *Amplitude, name=Amp-1, definition=SMOOTH STEP 0., 0., 0.01, 1. *Amplitude, name=tempxy, definition=USER, variables=2 ** ** MATERIALS ** *Material, name=Nickel *Density 8.9e-09, *Elastic 210000., 0.3 *Plastic 2000., 0. 2500., 0.2 ** ** INTERACTION PROPERTIES ** *Surface Interaction, name=Contact *Friction 0., ** ** BOUNDARY CONDITIONS ** ** Name: Boden Type: Displacement/Rotation *Boundary "RB-Knoten Unten", 2, 2 ** Name: Rotation Oben Type: Displacement/Rotation *Boundary "RB-Knoten Oben", 4, 4 "RB-Knoten Oben", 5, 5 "RB-Knoten Oben", 6, 6 ** Name: Rotation Unten Type: Displacement/Rotation *Boundary "RB-Knoten Unten", 4, 4 "RB-Knoten Unten", 5, 5 "RB-Knoten Unten", 6, 6 ** Name: Statbest Type: Displacement/Rotation *Boundary KnotenStatBestUnten, 1, 1 KnotenStatBestUnten, 3, 3 ** ** INTERACTIONS ** ** Interaction: Int-1 *Contact, op=NEW *Contact Inclusions, ALL EXTERIOR *Contact Property Assignment , , Contact ** ---------------------------------------------------------------- ** ** STEP: Belastung_1 ** *Step, name=Belastung_1, nlgeom=YES *Dynamic, Explicit , 0.01 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** BOUNDARY CONDITIONS ** ** Name: Belastung_1 Type: Displacement/Rotation *Boundary, amplitude=AMP-1 RP, 2, 2, -0.565 ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: Entlastung_1 ** *Step, name=Entlastung_1, nlgeom=YES *Dynamic, Explicit , 0.01 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** BOUNDARY CONDITIONS ** ** Name: Entlastung_1 Type: Displacement/Rotation *Boundary, amplitude=AMP-1 RP, 2, 2, 0.565 ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: VP_1 ** *Step, name=VP_1, nlgeom=YES *Dynamic, Explicit , 0.001 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** LOADS ** ** Name: VP_1 Type: Pressure *Dsload, op=NEW VP_Surface, VP, 0.00087 ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: Belastung_2 ** *Step, name=Belastung_2, nlgeom=YES *Dynamic, Explicit , 0.01 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** BOUNDARY CONDITIONS ** ** Name: Belastung_2 Type: Displacement/Rotation *Boundary, amplitude=AMP-1 RP, 2, 2, -1.13 ** ** LOADS ** ** Name: VP_1 Type: Pressure *Dsload, op=NEW ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: VP_2 ** *Step, name=VP_2, nlgeom=YES *Dynamic, Explicit , 0.001 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** LOADS ** ** Name: VP_2 Type: Pressure *Dsload, op=NEW VP_Surface, VP, 0.00087 ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: Entlastung_2 ** *Step, name=Entlastung_2, nlgeom=YES *Dynamic, Explicit , 0.01 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** BOUNDARY CONDITIONS ** ** Name: Entlastung_2 Type: Displacement/Rotation *Boundary, amplitude=AMP-1 RP, 2, 2, 1.13 ** ** LOADS ** ** Name: VP_2 Type: Pressure *Dsload, op=NEW ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: VP_3 ** *Step, name=VP_3, nlgeom=YES *Dynamic, Explicit , 0.001 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** LOADS ** ** Name: VP_3 Type: Pressure *Dsload, op=NEW VP_Surface, VP, 0.00087 ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: Belastung_3 ** *Step, name=Belastung_3, nlgeom=YES *Dynamic, Explicit , 0.01 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** BOUNDARY CONDITIONS ** ** Name: Belastung_3 Type: Displacement/Rotation *Boundary, amplitude=AMP-1 RP, 2, 2, -1.697 ** ** LOADS ** ** Name: VP_3 Type: Pressure *Dsload, op=NEW ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: VP_4 ** *Step, name=VP_4, nlgeom=YES *Dynamic, Explicit , 0.001 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** LOADS ** ** Name: VP_4 Type: Pressure *Dsload, op=NEW VP_Surface, VP, 0.00087 ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: Entlastung_3 ** *Step, name=Entlastung_3, nlgeom=YES *Dynamic, Explicit , 0.01 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** BOUNDARY CONDITIONS ** ** Name: Entlastung_3 Type: Displacement/Rotation *Boundary, amplitude=AMP-1 RP, 2, 2, 1.697 ** ** LOADS ** ** Name: VP_4 Type: Pressure *Dsload, op=NEW ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: VP_5 ** *Step, name=VP_5, nlgeom=YES *Dynamic, Explicit , 0.001 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** LOADS ** ** Name: VP_5 Type: Pressure *Dsload, op=NEW VP_Surface, VP, 0.00087 ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: Belastung_4 ** *Step, name=Belastung_4, nlgeom=YES *Dynamic, Explicit , 0.01 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** BOUNDARY CONDITIONS ** ** Name: Belastung_4 Type: Displacement/Rotation *Boundary, amplitude=AMP-1 RP, 2, 2, -2.262 ** ** LOADS ** ** Name: VP_5 Type: Pressure *Dsload, op=NEW ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: VP_6 ** *Step, name=VP_6, nlgeom=YES *Dynamic, Explicit , 0.001 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** LOADS ** ** Name: VP_6 Type: Pressure *Dsload, op=NEW VP_Surface, VP, 0.00087 ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: Entlastung_4 ** *Step, name=Entlastung_4, nlgeom=YES *Dynamic, Explicit , 0.01 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** BOUNDARY CONDITIONS ** ** Name: Entlastung_4 Type: Displacement/Rotation *Boundary, amplitude=AMP-1 RP, 2, 2, 2.262 ** ** LOADS ** ** Name: VP_6 Type: Pressure *Dsload, op=NEW ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: VP_7 ** *Step, name=VP_7, nlgeom=YES *Dynamic, Explicit , 0.001 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** LOADS ** ** Name: VP_7 Type: Pressure *Dsload, op=NEW VP_Surface, VP, 0.00087 ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: Belastung_5 ** *Step, name=Belastung_5, nlgeom=YES *Dynamic, Explicit , 0.01 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** BOUNDARY CONDITIONS ** ** Name: Belastung_5 Type: Displacement/Rotation *Boundary, amplitude=AMP-1 RP, 2, 2, -2.828 ** ** LOADS ** ** Name: VP_7 Type: Pressure *Dsload, op=NEW ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: VP_8 ** *Step, name=VP_8, nlgeom=YES *Dynamic, Explicit , 0.001 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** LOADS ** ** Name: VP_8 Type: Pressure *Dsload, op=NEW VP_Surface, VP, 0.00087 ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step ** ---------------------------------------------------------------- ** ** STEP: Entlastung_5 ** *Step, name=Entlastung_5, nlgeom=YES *Dynamic, Explicit , 0.01 *Bulk Viscosity 0.06, 1.2 ** ** Mass Scaling: Semi-Automatic ** Whole Model *Fixed Mass Scaling, factor=25. ** ** BOUNDARY CONDITIONS ** ** Name: Entlastung_5 Type: Displacement/Rotation *Boundary, amplitude=AMP-1 RP, 2, 2, 2.828 ** ** LOADS ** ** Name: VP_8 Type: Pressure *Dsload, op=NEW ** ** OUTPUT REQUESTS ** *Restart, write, number interval=1, time marks=NO ** ** FIELD OUTPUT: F-Output-1 ** *Output, field, variable=PRESELECT, number interval=100 ** ** HISTORY OUTPUT: H-Output-5 ** *Output, history *Node Output, nset="RB-Knoten Oben" U2, ** ** HISTORY OUTPUT: H-Output-4 ** *Node Output, nset="RB-Knoten Unten" RF2, ** ** ** HISTORY OUTPUT: H-Output-1 ** *Output, history, variable=PRESELECT ** HISTORY OUTPUT: SENSOR ** *Output, history, sensor, name=SENSOR *Node Output, nset=RP RF2, ** ** HISTORY OUTPUT: SENSOR2 ** *Output, history, sensor, name=SENSOR2 *Node Output, nset=RP U2, *End Step