@echo off rem ****************************************************************************** rem Copyright: Software Implementation Design Team @ Siemens PLM Software rem ****************************************************************************** rem rem REV AUTHOR DATE COMMENT for custom_nx100.bat rem ==== ========== ========== ============================================ rem 1.00 SIDT Version NX 10.0 1.00 rem 1.01 SIDT Version NX 10.0 1.01 rem ============================================================================= rem rem ------------------------------------------------------------------------------ rem debug variable to set echo on rem ------------------------------------------------------------------------------ if "%SIDT_DEBUG%" == "1" echo on rem ------------------------------------------------------------------------------ rem the following entries are only examples rem ------------------------------------------------------------------------------ rem if /i "%COMPUTERNAME%" == "rcadws39" set UGII_PLOT_NODE=rcadws39 rem if /i "%COMPUTERNAME%" == "rcadws39" set UGII_PRINTER=\\rcadws28\lj4l rem if /i "%COMPUTERNAME%" == "rcadws39" set UGII_FLEX_BUNDLE=MFG rem if /i "%USERNAME%" == "maier" set UGII_PRINTER=\\host\share rem if /i "%COMPUTERNAME%" == "rcadws39" goto set_cam_var rem goto continue rem :set_cam_var rem set UGII_CAM_MOM=1 rem set UGII_CAM_POST_CONFIG_FILE=%SPLM_SHR_DIR%\%NX_SHR_VERSION_DIR%\%NX_PLATFORM%\mach\custom\ugpost\mom_config.dat rem set UGII_NCD_DIR=%SPLM_SHR_DIR%\%NX_SHR_VERSION_DIR%\%NX_PLATFORM%\mach\custom\tape\ rem set UGII_PPJ_DIR=%SPLM_SHR_DIR%\%NX_SHR_VERSION_DIR%\%NX_PLATFORM%\mach\custom\ugpost\ rem :continue rem ------------------------------------------------------------------------------ rem rem Customer specific environment rem rem ----------------------------------------------------------------------------- if "%NX_INSTALLED%" == "0" goto no_nx_installed rem ------------------------------------------------------------------------------ rem set UGII_SITE_DIR for site specific customer defaults file rem the only modification in this file is to set NX to metric and define the ugcolor.cdf file rem this is SIDT default rem comment out the variable UGII_LOCAL_USER_DEFAULTS in ugii_env.dat rem ------------------------------------------------------------------------------ set UGII_SITE_DIR=%SPLM_SHR_DIR%\%NX_SHR_VERSION_DIR%\%NX_PLATFORM%\ugii rem set UGII_LOCAL_USER_DEFAULTS=%SPLM_SHR_DIR%\%NX_SHR_VERSION_DIR%\%NX_PLATFORM%\ugii\startup\nx90_%username%.dpv rem ------------------------------------------------------------------------------ rem set SDI plotting config and print_submit directory rem ------------------------------------------------------------------------------ set UGII_SDI_CONFIG=%SPLM_SHR_DIR%\%NX_SHR_VERSION_DIR%\%NX_PLATFORM%\nxplot\config set UGII_SDI_SERVER_CFG_DIR=%UGII_SDI_CONFIG%\pm_server rem set UGII_SDI_OVERRIDE_HOME=%UGII_SDI_CONFIG% rem set UGII_SDI_BPS_JOBS_DIR=%UGII_SDI_CONFIG% rem ------------------------------------------------------------------------------ rem set variable UGII_UGDOC_BASE for shared documentation NX10 with Doc Server rem fill in the HOSTNAME:PORT from the current PLM Documentation Server rem ------------------------------------------------------------------------------ set UGII_UGDOC_BASE=http:\\LOCALHOST:8181 rem ----------------------------------- rem ENDRU ANPASSUNG rem ---------------------------------- set UGII_TEMPLATE_DIR=%SPLM_SHR_DIR%\%NX_SHR_VERSION_DIR%\%NX_PLATFORM%\ugii\templates set MOLDWIZARD_DIR=%SPLM_SHR_DIR%\%NX_SHR_VERSION_DIR%\%NX_PLATFORM%\moldwizard :no_nx_installed rem ------------------------------------------------------------------------------ rem set UGS license server rem ------------------------------------------------------------------------------ rem set UGS_LICENSE_SERVER=28000@hostname rem ------------------------------------------------------------------------------ rem set UGS license server (new version) rem ------------------------------------------------------------------------------ rem set SPLM_LICENSE_SERVER=28000@hostname rem ------------------------------------------------------------------------------ rem set bundle variable rem ------------------------------------------------------------------------------ rem set UGII_FLEX_BUNDLE= set UGS_LICENSE_BUNDLE=MILLFOUND rem ------------------------------------------------------------------------------ rem set BCT license server or file rem ------------------------------------------------------------------------------ rem if exist %SPLM_SHR_DIR%\bct_iecs\bct_license\bctv230.dat set BCT_LICENSE_FILE=%SPLM_SHR_DIR%\bct_iecs\bct_license\bctv220.dat rem set BCT_LICENSE_FILE=27003@hostname rem ------------------------------------------------------------------------------ rem set Schematics Variablen rem ------------------------------------------------------------------------------ rem LTX_BASE_DIR Sucht die Software von LTD… rem set LTX_BASE_DIR=D:\Siemens\Schematics\10.0\ugs_basedir rem UG_SCHEMATICS_LIB sucht nach der Schematics Bibliothek rem set UG_SCHEMATICS_LIB=D:\Siemens\ReUseLibrary\Schematics\