/PREP7 /TITLE, 2016-06-11, Konzentrische Leiter, Wirbelstromverluste, AZ=0 / SF=INF ET,1,PLANE233 ! PLANE233, AZ DOF, (FOR AIR) ET,2,PLANE233,1 ! PLANE233, AZ VOLT DOF, (FOR CONDUCTOR) ET,3,PLANE233,1 ! PLANE233, AZ VOLT DOF, (FOR CONDUCTOR) ET,4,PLANE233 ! PLANE233, AZ DOF, (FOR AIR) ET,5,INFIN110,0,1 ! INFIN110, AZ, 8-node quadrilateral EMUNIT,MKS ! DEFINE SYSTEM UNITS rc = 3e-3 ! outer radius of axial conductor ri = 16.33e-3 ! inner radius of coaxial conductor ro = 19.33e-3 ! outer radius of coaxial conductor Ipeak = 100.0 ! current of axial conductor f = 50 ! frequency (Hz) sigma = 1.0e6 ! material conductivity mur = 1 ! material permeability MP,MURX,1,1 MP,MURX,2,1 MP,RSVZ,2,1/sigma MP,MURX,3,1 MP,RSVZ,3,1/sigma k, 1, 0, 0, 0 ! center of the circles -> PCENT k, 10, 1e-3, 0, 0 ! Keypoint for zero degree location -> PZERO k, 11, 0, 0, 1e-3 ! Keypoint defining axis of circle (along with PCENT) -> PAXIS numstr, KP, 21 numstr, LINE, 21 circle, 1, rc, 11, 10, 360, 4 ! Sets KP 21-24 and Lines 21-24 numstr, KP, 31 numstr, LINE, 31 circle, 1, ri, 11, 10, 360, 4 ! Sets KP 31-34 and Lines 31-34 numstr, KP, 41 numstr, LINE, 41 circle, 1, ro, 11, 10, 360, 4 ! Sets KP 41-44 and Lines 41-44 numstr, KP, 51 numstr, LINE, 51 circle, 1, ro+ro/2, 11, 10, 360, 4 ! Sets KP 51-54 and Lines 51-54 numstr, KP, 61 numstr, LINE, 61 circle, 1, ro+ro, 11, 10, 360, 4 ! Sets KP 61-64 and Lines 61-64 !rectng,-2*ro,2*ro,-2*ro,2*ro !k, 61, 2*ro, 2*ro, 0 !k, 62, -2*ro, 2*ro, 0 !k, 63, -2*ro, -2*ro, 0 !k, 64, 2*ro, -2*ro, 0 !l, 61, 62, !l, 62, 63, !l, 63, 64, !l, 64, 61, AL, 21, 22, 23, 24 ! current-carrying conductor area -> AREA 1 AL, 21, 22, 23, 24, 31, 32, 33, 34 ! air area -> AREA 2 AL, 31, 32, 33, 34, 41, 42, 43, 44 ! concentric conductor area -> AREA 3 AL, 41, 42, 43, 44, 51, 52, 53, 54 ! air area -> AREA 4 AL, 51, 52, 53, 54, 61, 62, 63, 64 ! infinite area -> AREA 5 ASEL,S,AREA,,4 AATT,1,,4 ! SET ATTRIBUTES FOR AIR ASEL,S,AREA,,3 AATT,3,,3 ! SET ATTRIBUTES FOR CONDUCTOR ASEL,S,AREA,,2 AATT,1,,1 ! SET ATTRIBUTES FOR AIR ASEL,S,AREA,,1 AATT,2,,2 ! SET ATTRIBUTES FOR CONDUCTOR asel,all lsel,s,line,,61,64,1 lsel,a,line,,51,54,1 lesize,all,,,8 mshape,0,2d ! mapped mesh with quads mshkey,2 amesh,5 lsel,s,line,,41,44,1 lesize,all,,,90 mshape,1,2d mshkey,0 amesh,4 lsel,s,line,,31,34,1 lesize,all,,,90 mshape,0,2d mshkey,2 amesh,3 lsel,s,line,,21,24,1 lesize,all,,,5 mshape,1,2d mshkey,0 smrtsize,10 amesh,1,2 ESEL,S,MAT,,2 ! SELECT ALL NODES IN CONDUCTOR NSLE,S CP,1,VOLT,ALL ! COUPLE ALL NODES IN VOLT *GET,AREA,AREA,1,AREA ! GET AREA OF CONDUCTOR *GET,N1,NODE,,NUM,MIN ! SELECT A NODE IN THE CONDUCTOR F,N1,AMPS,Ipeak ESEL,ALL NSEL,S,EXT sf,all,inf ! set infinite surface flag !D,ALL,AZ,0 ! SET FLUX PARALLEL B.C. ESEL,S,MAT,,3 ! SELECT ALL NODES IN CONDUCTOR NSLE,S CP,2,VOLT,ALL ! COUPLE ALL NODES IN VOLT ESEL,ALL NSEL,ALL FINISH /SOLU ANTYPE,HARMIC ! HARMONIC ANALYSIS HARFRQ,f SOLVE FINISH /POST1 SET,1,1 ! RETRIEVE REAL SOLUTION ETABLE,JT,NMISC,1 ! STORE TOTAL CURRENT DENSITY ESEL,MAT,3 ! SELECT COPPER ONLY PLETAB,JT,1 ! DISPLAY TOTAL CURRENT DENSITY powerh