/COM,ANSYS RELEASE 2021 R1 BUILD 21.1 UP20201109 22:15:18 *** WARNING *** CP = 4.938 TIME= 22:15:39 Shape testing revealed that 288 of the 29160 new or modified elements violate shape warning limits. To review test results, please see the output file or issue the CHECK command. *** WARNING *** CP = 10.516 TIME= 22:15:44 Shape testing revealed that 288 of the 29160 new or modified elements violate shape warning limits. To review test results, please see the output file or issue the CHECK command. *** WARNING *** CP = 11.281 TIME= 22:15:44 After NUMMRG,NODE, node 38540 (and possibly others) is associated with more than one solid model entity. Future commands which depend on the node to solid model connectivity (meshing, mesh clearing, solid boundary condition transfer, etc.) may not operate properly. NUMMRG,KP may correct this problem. --> Die Meldungen oberhalb von hier sind egal, da sie das Ergebnis zunächst nicht beeinflussen und nur Warnungen sind. Doch die Meldungen unterhalb von hier...(ich habe nur die Meldungen für einen Knoten abgespeichert, es sind aber einige betroffen.) *** ERROR *** CP = 11.438 TIME= 22:15:45 Brick element 1378 has an aspect ratio of 1.E+20, which exceeds the error limit of 1000000. *** WARNING *** CP = 11.609 TIME= 22:15:50 Brick element 1378 has a pair of opposite edges that are 115.2 degrees away from being parallel. This exceeds the warning limit of 100 degrees. *** WARNING *** CP = 11.672 TIME= 22:15:50 Brick element 1378 has an angle between adjacent edges of 170.4 degrees, which exceeds the warning limit of 165 degrees. *** WARNING *** CP = 11.734 TIME= 22:15:50 Brick element 1378 has a face with a warping factor of 0.2083, which exceeds the warning limit of 0.2. *** ERROR *** SUPPRESSED MESSAGE CP = 11.781 TIME= 22:15:50 Brick element 1378 has a zero or negative determinant of the Jacobian matrix at one of its sampling locations. Midside nodes, if any, may be poorly positioned. *** ERROR *** SUPPRESSED MESSAGE CP = 11.781 TIME= 22:15:50 Element 1378 is an improperly connected degenerate brick element. The database may be corrupted at this point. To proceed, clear the current mesh and create a new one or try to resume a saved database with the RESUME command.